目錄:福祿克測試儀器(上海)有限公司>>溫度>>固定點(diǎn)>> 5901A水三相點(diǎn)瓶

水三相點(diǎn)瓶
  • 水三相點(diǎn)瓶
參考價(jià) 面議
具體成交價(jià)以合同協(xié)議為準(zhǔn)
參考價(jià) 面議
具體成交價(jià)以合同協(xié)議為準(zhǔn)
  • 品牌 FLUKE/福祿克
  • 型號(hào) 5901A
  • 廠商性質(zhì) 生產(chǎn)商
  • 所在地 上海市
屬性

產(chǎn)地類別:進(jìn)口 應(yīng)用領(lǐng)域:綜合

>

更新時(shí)間:2024-11-20 17:25:52瀏覽次數(shù):452評(píng)價(jià)

聯(lián)系我們時(shí)請(qǐng)說明是化工儀器網(wǎng)上看到的信息,謝謝!

同類優(yōu)質(zhì)產(chǎn)品

更多產(chǎn)品
產(chǎn)地類別 進(jìn)口 應(yīng)用領(lǐng)域 綜合
水三相點(diǎn)瓶 5901A經(jīng)過多次蒸餾的海洋水,經(jīng)過嚴(yán)格抽真空和密封以維持水的高純度,小于0.0001℃的擴(kuò)展不確定度實(shí)現(xiàn)0.01℃溫度。外殼為硼硅玻璃或石英,多種尺寸滿足不同需求。

The triple point of water (TPW) is not only the most accurate and fundamental temperature standard available, it’s also one of the least expensive and simplest to use.

Water cells are essential!

Triple point of water cells fill four critical purposes. First, they provide the most reliable way to identify unacceptable thermometer drift between calibrations—including immediately after a calibration if the thermometer has been shipped. Interim checks are critical for maintaining confidence in thermometer readings between calibrations. Second, they provide a critical calibration point with unequaled uncertainties

Third, for users who characterize probes using ratios (that is, they use the ratios of the resistances at various ITS-90 fixed points to the resistance of the thermometer at the triple point of water, indicated by “W"), interim checks at the triple point of water allow for quick and easy updates to the characterizations of critical thermometer standards, which can be used to extend calibration intervals.

And lastly, the triple point of water is where the practical temperature scale (ITS-90) and the thermodynamic temperature scale meet, since the triple point of water is assigned the value 273.16 K (0.01 °C) by the ITS-90 and the Kelvin is defined as 1/273.16 of the thermodynamic temperature of the triple point of water.

Good triple point of water cells contain only pure water and pure water vapor. (There is almost no residual air left in them.) When a portion of the water is frozen correctly and water coexists within the cell in its three phases, the “triple point of water" is realized. Fluke Calibration water cells achieve this temperature with expanded uncertainties of less than 0.0001 °C and reproducibilities within 0.00002 °C.

In simple terms, water cells are made from just glass and water, but there’s much more to it than that! Forstarters, that’s not just any water in there.

Heavy water

Fluke Calibration cells contain carefully and repetitively distilled ocean water and are meticulously evacuated and sealed to maintain an isotopic composition nearly identical to the international standard, “Vienna Standard Mean Ocean Water," or “VSMOW."

The oxygen atoms found in most water are predominantly comprised of eight protons and eight neutrons (16O). Some oxygen atoms, however, have an extra neutron (17O) or two (18O). Similarly, the hydrogen atoms in water normally contain only a single proton (1H), but sometimes contain a neutron also (2H), resulting in“heavy" water. These isotopes coexist in varying proportions in ocean water, polar water, and continental water, with ocean water being the heaviest. The ITS-90 recommends that water cells be made from water with “substantially the isotopic composition of ocean water." Research has shown that TPW errors associated with isotopic composition can be as large as0.00025 °C. The uncertainty contribution from VSMOW errors in Fluke Calibration cells is less than ± 0.000007 °C. That’s seven micro-Kelvin! Fluke Calibration offers two options for verifying the isotopic composition of any purchased water cell, both at nominal costs. We can submit to a testing laboratory a sample of water taken from your own cell (after it was completely manufactured, so you get a valid comparison) and give you the test report. Or we can send that water sample to you in a sealed ampoule for you to conduct your own tests. We can even provide multiple samples from the same cell (virtually as many as you’d like) so you can check for changes over time.

Impurities

Further, the potential for errors due to water impurity is even greater than the errors from isotopic composition. Fluke Calibration cells undergo multiple distillation processes and utilize special techniques to retain water purity. Among other things, our primary standards scientists are able to connect quartz cells directly to the glass distillation system without using coupling hardware that may invite contamination.

Glass vs. quartz

Most Fluke Calibration water cells may either be purchased with borosilicate glass or with fused silica (“quartz") housings. What’s the difference? Glass is less expensive than quartz, but it’s also more porous, allowing impurities to pass through it over time. Research indicates that cells made from glass typically drift about 0.00006 °C per year.

Many sizes

Fluke Calibration cells come in four general sizes. Models 5901A, 5901C, and 5901D each come in either quartz or glass shells and include 265 mm of thermometer immersion depth. The primary difference between these models (other than the arm on the 5901A) is the inside diameter of the probe well. (See chart at right and note that the inside diameter of the 5901C cells varies with the shell material). A variety of baths is available, which can maintain the triple point within these cells for many weeks. Accredited (NVLAP) test certificates are available with any cell under our Model 1904-TPW. 5901A cells include an arm that can be used as a handle, a hook, or a McLeod gauge to demonstrate how much residual air is trapped in the cell. Carefully developed manufacturing processes at Fluke Calibration keep the air bubble in a quartz cell as small as the air bubble in glass cells. A fourth size, the 5901B cell, comes in a glass version and is significantly smaller than the other cells. It is designed for use in our Model 9210 Maintenance Apparatus, which automates the realization and maintenance of the TPW. The 9210-5901B combination is perfect for both calibrating thermometers and providing periodic checks of sensor drift.

Accessories

For simplest realization of the TPW in our larger cells, the Model 2031 “Quick Stick" Immersion Freezer uses dry ice and alcohol to facilitate rapid formation of an ice mantle within the cell without requiring constant intervention while the mantle forms. Insurance is also available for each water cell purchased from Fluke Calibration. Water cells are not difficult to handle nor is the TPW difficult to realize, but they are delicate and accidents do happen. For a nominal fee, we’ll insure your cell in one-year increments. If something goes wrong, just let us know and we’ll replace your cell. No questions asked. There is no tool available to temperature metrologists more valuable than a reliable triple point of water cell. Fluke Calibration cells use the right water, right enclosures, and right manufacturing methods to ensure you get the best cells available in the world.

img1

img2



會(huì)員登錄

請(qǐng)輸入賬號(hào)

請(qǐng)輸入密碼

=

請(qǐng)輸驗(yàn)證碼

收藏該商鋪

標(biāo)簽:
保存成功

(空格分隔,最多3個(gè),單個(gè)標(biāo)簽最多10個(gè)字符)

常用:

提示

您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~
在線留言

會(huì)員登錄

請(qǐng)輸入賬號(hào)

請(qǐng)輸入密碼

=

請(qǐng)輸驗(yàn)證碼

收藏該商鋪

該信息已收藏!
標(biāo)簽:
保存成功

(空格分隔,最多3個(gè),單個(gè)標(biāo)簽最多10個(gè)字符)

常用:
熱線電話 在線詢價(jià)
主站蜘蛛池模板: 国产亚洲欧美第二区| 男妓跪趴把舌头伸进我的嘴巴| 白洁被高振干到九点多电影叫什么| CHINESE叫床对白VIDEOS| 亚洲精品偷拍AV一区二区| 黄乱色伦短篇小说TXT下载| 饥渴少妇A片AAA毛片小说| 人妻中文字幕乱人伦在线| 日韩亚洲综合av| 无码中文字幕热热久久| 精选国产高清在线| 欧美精品亚洲精品日韩精品| WWW夜片内射视频在观看视频| 国模小婕私拍鲜嫩玉门| 精品久久亚洲熟女| 国产精品扒开腿做爽爽爽A片软件| 欧美日韩黄色网| 亚洲欧洲久久| 午夜4k最新福利| 国产精品欧美久久| 色噜噜狠狠亚洲综合在爱| 欧美三日本三级少妇99印度| 久久久乱码精品亚洲日韩小说| 免费又粗又硬进去好爽A片| yy主播不雅视频| 99成人做爰A片免费看网站| 国产精品久久久久久久密密| 久99视频精品免费观看福利| 久久久久亚洲精品影视| 久久毛片免费看一区二区三区| 日韩精品无码二三区A片| 国产麻豆亚洲精品一区二区| 日韩人妻中文在线| 亚洲欧洲校园自拍都市| 特级精品毛片免费观看| 色爱区区域综合网| 欧美写真视频一区| 久久久久久最新| 久久精品国产久精国产| 男人天堂亚洲av| 午夜福利18禁视频|