trifield電磁、微波輻射測量儀
英文簡單使用說明

using the trifield meter
a knob on the front has six positions: off, battery test, two magnetic field sensitivities (0.5-100 milligauss at 60 hz, and 0.2-3 milligauss at 60 hz, the second sensitivity to measure weak fields more accuray), electric field and radio/microwave power density. the meter face is analog (needle type). a needle reading of one-third of full scale corresponds to either 3 milligauss (or 0.6 milligauss) @ 60 hz, 3 kilovolts/meter @ 60 hz, or 0.04 mw/cm2 respectively in the magnetic, electric, and radio/microwave field settings. average magnetic field strength in north american homes and offices is 1-3 milligauss, so the meter is labeled "high" above these levels.
magnetic field detection 
in most homes or offices, some areas are "hot" spots with readings in the high range. most often, this is caused by magnetic fields, which come largely from unpaired internal wiring. (contrary to popular belief, power transmission lines and transformers do not generally contribute as much magnetic field as does internal wiring.) other magnetic sources include video displays, motorized clocks and other equipment, electric blankets and heaters, fluorescent lights and light dimmers, and the transformers that are inside consumer devices. much of the total field strength is from frequencies that are harmonics or multiples of 60 hz (120 hz, 180 hz, etc.) and 17,000 hz of video displays. cars (especially near the front floorboard of electronic ignition cars) and motorcycles have fairly strong fields that are at frequencies higher than 60 hz. magnetic field is difficult to shield, but sheet steel is somewhat effective.
electric field detection
a few areas in most homes read high in the electric field setting. these include areas near improperly grounded equipment, the front of video screens, and fluorescent lights. most of these fields can be easily shielded using a grounded metal screen or foil; vdt screens of this type are readily available. you can greatly reduce the strength of an electric field just by placing your hand in front of the source. this effect can be seen using a trifield meter.
microwave detection
occasionally, certain areas read high in the radio/microwave setting. these include door seals around microwave ovens, and cellular phones (but not regular radio phones, which are very low-power). radio/microwaves can be shielded in the same way as electric fields, although the lower frequency radio waves are not shielded by your hand as easily as microwaves are. (metal screens will shield both.) in the united states, radars and fm transmitters can legally expose residents to moderay high power levels (as high as 10 mw/cm2 briefly or .57 mw/cm2 near cellular towers), but such exposure is not common.
reducing field exposure
some equipment is sensitive to magnetic fields (ie, a high resolution color monitor may not function properly above 30 milligauss). by seeing "hot" spots in your home and office, you can move equipment or furniture to reduce exposure. if a room has a "hot" spot, fields are generally much weaker elsewhere in that same room.
the trifield broadband meter
this was designed as a more general electromagnetic measurement tool. it detects electric fields from power line frequencies up through 2.5 ghz. this fills in the gap from 100 khz to 50 mhz, which includes many amateur radio frequencies so that antenna radiation patterns can be measured. the broadband detects magnetic fields up through 100 khz, as does the standard trifield meter.
the ac magnetic section is identical to that of the standard trifield meter and has several uses. it can detect which of several wires or transformers is carrying current, and help determine appropriate placement of magnetically sensitive equipment. it can also help to reduce personal exposure to fields. most users prefer a magnetic section which is frequency-weighted, and calibrated at 60 hz. however, a flat frequency response version (50 hz to 500 hz) is also available for the ac magnetic section. this is the same price as the regular frequency-weighted version (which has sensitivity proportional to frequency from 50 hz to 500 hz.)
the ac electric section is also identical to that of the standard trifield meter and can be used to determine whether an ac line is hot or neutral, even through a wall. it can easily detect by proximity which side of a wall outlet or which wire of an extension cord is hot. it can also detect improper grounding, as well as the extensive electric fields from video monitors and fluorescent lights. 
the radio/microwave section detects vertical electric fields parallel to the long axis of the meter. range is 10v/m to 1 kv/m (0.026 mw/cm2 to 260 mw/cm2) and is frequency-flat from 100 khz to 2.5 ghz. accuracy is +/-30%. it is used to detect on-air status of transmitters (or to detect concealed transmitters), to check microwave ovens or other microwave equipment for leakage, and to look for rfi sources. 
for radio waves, magnetic field strength is proportional to electric field strength. therefore only electric or magnetic need be measured. in a radio wave, one milligauss corresponds to 30 volts per meter, which are the rms magnetic and electric fields for a power density of 0.24 milliwatt/cm2. the power density increases as the square of the field strength, and the field strength decreases as the inverse distance from the transmitting antenna. 
magnetic field detection
the magnetic section consists of three ferrite-core coils pointing in the x, y, and z directions and located in the geometric center of the meter. non-linear circuitry combines the signals of these three into a true magnitude of the field strength, independent of which direction the meter is pointed.

in most homes and offices, a large fraction of the total magnetic field is at frequencies above 60 hz. a trifield meter, when exposed to a 3 milligauss field, will read "3" if the frequency of the field is 60 hz, but it will read "6" if the 3 milligauss field is at 120 hz. in contrast, a non-frequency-weighted (the flat response version of the trifield) meter will read "3" in both cases, and a 60 hz-only meter will read "3" and "0" respectively (even though in the 120 hz case, the current induced in a conductive body is twice as much.) 
electric field detection
the electric section consists of three metal plates under the meter face. because the meter housing is plastic, the electric fields can penetrate through to the plates, which are also arranged to detect ac electric fields in the x, y, and z directions. circuitry similar to the magnetic section converts the signals into an electric field signal which is frequency-weighted. sensitivity is 0.5-100 kilovolts per meter (kv/m) at 60 hz, with resolution of 0.5 kv/m (1 kv/m =1000 v/m). accuracy at mid-range is +/-30%.
radio and microwave detection
radio and microwaves are composed of a particular combination of electric fields and magnetic fields that is self-sustaining. for frequencies below about 100 mhz (100 million hz) the principle effect on a conducting body is from the magnetic field part only. this is because the electric field component of radio waves produces much weaker currents in the body than does the magnetic field unless the wavelength of the waves is smaller than the height of the body. low-frequency electric fields by themselves can be strong enough to cr-eate significant current, but only if they are from sources other than true radio waves.
the radio/microwave section has a small l-shaped antenna in the front. the signal is amplified and converted to a power density magnitude, calibrated at typical home microwave oven frequency (2 ghz). it reads 0 to 1 milliwatt/square centimeter. the resolution at the bottom of the range is 0.01 mw/cm2, which is the russian standard for maximum exposure, and is the most conservative standard of any country. in contrast the us legal maximum is 1000 times higher, at 10 mw/cm2, but only brief exposure is allowed at this level. as mentioned, a true radio wave is a particular combination of electric and magnetic fields. a radio wave strength of 0.01 mw/cm2 has 0.006 kv/m and 0.2 milligauss, respectively, of electric and magnetic field (rms averaged), while a strength of 1 mw/cm2 corresponds to 0.06 kv/m and 2 milliguass. typical accuracy is within a factor of two. variations are caused by reflections off the user"s hand and body.
北京東方圓通科技發展有限公司
地址:北京市昌平區西環路24號
:0086-(一號通)、69722055,   69728262,  69722157,  69722398,  
0086-
: dongfangyt2@tom.com 
http://www.orientaltec.com

相關產品

免責聲明

  • 凡本網注明“來源:化工儀器網”的所有作品,均為浙江興旺寶明通網絡有限公司-化工儀器網合法擁有版權或有權使用的作品,未經本網授權不得轉載、摘編或利用其他方式使用上述作品。已經本網授權使用作品的,應在授權范圍內使用,并注明“來源:化工儀器網”。違反上述聲明者,本網將追究其相關法律責任。
  • 本網轉載并注明自其他來源(非化工儀器網)的作品,目的在于傳遞更多信息,并不代表本網贊同其觀點和對其真實性負責,不承擔此類作品侵權行為的直接責任及連帶責任。其他媒體、網站或個人從本網轉載時,必須保留本網注明的作品第一來源,并自負版權等法律責任。
  • 如涉及作品內容、版權等問題,請在作品發表之日起一周內與本網聯系,否則視為放棄相關權利。
企業未開通此功能
詳詢客服 : 0571-87858618
主站蜘蛛池模板: 精品欧美一级片| 青青草原男人天堂| 亚洲欧美日韩国产专区一区| 欧美做愛坉片| 口述她张开腿让我添| 久久久久久91| 中文有码中文字幕免费视频| 色综合AV亚洲超碰少妇| BL肉YIN荡受NP各种PLAY男男| 男人阁久久久久成人精品天堂| 91麻豆国产香蕉久久精品| 亚洲人成在线观看网站无码| 99久久人妻无码精品系列性欧美| 蜜臀AV久久国产午夜福利软件| 日韩中文字幕在线观看视频| 丁香婷婷综合激情五月色| 伦电影网中文字幕| 国产偷国产偷亚州清高APP| 久久精品99久久久久久| 久久久久亚洲av毛片麻豆| 开心五月色婷婷综合开心网| 五月综合激情婷婷六月色窝| 亚洲三级在线| 中文字幕aⅴ人妻一区二区| 国产午夜福利片| 日韩亚洲综合精品国产| 久久精品国产亚洲av热一区| 久久草在线视频国产一| 亚洲图片欧美文学小说激情| 久久人妻福利中文字幕日韩| 亚洲区激情区图片小说区| 韩国电影片理论| 成人香蕉视频在线| AV无码AV吞精久久免费| 欧美日韩三区在线| 推到小莉萝稚嫩H| 中文字幕日韩精品亚洲| 国产精品 中文字幕 亚洲 欧美| 久久综合亚洲精品| 欧美成人se01短视频在线看| 免费不卡在线观看av|