ISO16925-2014涂料和清漆耐高壓水噴射的測定

時間:2019/9/26閱讀:2549
分享:

 

上海鼎徵儀器儀表設備有限公司 蒸汽噴射試驗機滿足測試規范汽車廠家:寶馬、奔馳、通用、大眾、福特、沃爾沃等規范(AA-0136、DIN 55662、ISO16925,DBL 7381,GM9531P、PV1503VOLVO STD 423-0015,VOLVO VCS 1029 54719、FLTM BO 160-04、MS210-07PSA D23 5376,Renault D25 2018/-A-2001 ,GMW16745-2012方法B,TPJLR-52.561-2009

1 Scope  上海鼎徵儀器儀表設備有限公司
This International Standard specifies a test method for the assessment of the resistance of coatings to
pressure water-jetting. The test method simulates the effects pressure water-jetting has on a coating.
5 Apparatus and materials
Ordinary laboratory apparatus, together with the following:
5.1 Pressure water-jet, consisting of a high-pressure pump and a nozzle.
A high-pressure pump conveys the water from a storage bin. To avoid influences from variations in
pressure, it is necessary that the pressure and the volumetric flow rate be adjustable at the nozzle
described below.
The water temperature shall be adjustable to ± 2 °C.
The temperature shall be adjusted in accordance with Annex A. Necessary safety devices on the pressure
side of the unit, as e.g. pressure relief valve and by-pass valve, shall exist. If the jetting is unsteady, a flow
calming section may be installed in front of the nozzle. A pulsation of the water jet at the opening of the
pump is inadmissible. In order to reach a reproducible result, the nozzle shall be solidly mechanically
fixed and the test specimen shall be secured against slipping. For the adjustment of the volumetric flow
rate, a nozzle with a jet angle of 25° and a volumetric flow rate of 6 l/min at 2 MPa (20 bar) is required
(see Annex A).
The following technical data should be attainable:
— volumetric flow rate: 8 l/min to 14 l/min
— pressure: 4 MPa (40 bar) to 13 MPa (130 bar)
— temperature: 20 °C to 80 °C
— jetting time: 10 s to 300 s
 


Figure 1 shows the schematic construction of a pressure water-jet apparatus which is specially built for these tests.
 
Key
1 flow calming section
2 high-pressure valve, height adjustable
3 test specimen
4 clamping element  
5 feed tank
6 floating valve with filter
7 water shortage safeguard
8 heating
9 base frame, moveable
10 temperature sensor  
11 high-pressure pump
12 by-pass valve  
13 pressure relief valve
14 pressure transmitter
8.1 Introducing the cut or the scribe  上海鼎徵儀器儀表設備有限公司
Make sure that the test specimen is securely fastened when introducing the cut or the scribe.
Introduce both of the cuts or scribes vertically through the coating into the substrate using the cutting
or scribing tool, as shown in Figure 2. The depth of the cut or scribe into the substrate should be as
minimal as possible. The length of the first cut or scribe shall be at least 100 mm, if the geometry of the
part allows that. At an angle, introduce a second cut or scribe with a minimum length of 20 mm. The
cuts or scribes shall be introduced straight-line at an angle of approximately 30°. An automatic cutting
or scribing device may be used. Residues of the coating shall be removed from the cut or scribe.
NOTE The depth of the cut or scribe into the substrate influences the result.
The cutting or scribing tools should be checked regularly and replaced if necessary.

   Figure 2 — Introducing the cuts or scribes (St Andrew’s cross)


8.2 Testing
After inserting the test specimen into the apparatus (e.g. using a spacer block), calibrate the space
between test specimen and nozzle.
Operate the pressure water-jetting apparatus at room temperature.
Three test methods (A, B, or C – see Table 1) are preferred as well as three possible scribing tools (C, L, or
S – see 5.3). The test method to be applied, the scribing or cutting tool to be used, and the water pressure
shall be agreed.
Table 1 — Test methods  上海鼎徵儀器儀表設備有限公司
 

Test methodWater Temperature
Impact angle Space between nozzle and sample mmFlow rate
L/min
Duration of
jetting
A60±290±2100±111.3±0.230±1
B60±290±2100±111.3±0.260±1
C60±290±2100±111.3±0.260±1

 
For jetting, deionized water should be used.
When using automatic and manual devices, fasten the test specimen so that the water jet impacts as
shown in Figure 3. The jet impacts in the middle above the point of intersection onto the longer one of both cuts/scribes.


Figure 3 — Jetting area

9 Evaluation
9.1 General
Damage is recognizable when the coating loosens or flakes, regardless of which coat sustains the damage.
9.2 Evaluation with pictures to compare
Carry out the evaluation visually, comparing the specimen with the pictures.
In the course of the visual evaluation, a characteristic value is laid down by comparing with the
illustrations in Figures 4 to 9. A characteristic value between 1 and 5 results, depending on the degree
of damage. No damage corresponds to the characteristic value 0. In addition to the evaluation, if
applicable, the attribution of the separation from the main separation level or to the respective film
shall be indicated.
The result of the visual assessment is indicated in dependence of the applied method, for example:
— method A: characteristic value A;
— method B: characteristic value B;
— method C: characteristic value C.
NOTE In addition, by measuring the areas of flaking (maximum width, in millimetres, or area, in square
millimetres), the overall damage can be evaluated. The overall damage is calculated by summing up all damaged
areas of the test specimen. Even the smallest areas of flaking are measured and calculated, and all areas added to
the overall damage.

Figure 5 — Characteristic value 1 for pressure water-jet damage

Figure 6 — Characteristic value 2 for pressure water-jet damage


Figure 7 — Characteristic value 3 for pressure water-jet damage

Figure 8 — Characteristic value 4 for pressure water-jet damage

Figure 9 — Characteristic value 5 for pressure water-jet damage

 
Annex A
(normative)
Calibration of the test apparatus
A.1 Apparatus and materials
Ordinary laboratory apparatus, as well as the following.
A.1.1 Temperature measuring device, with sensor, capable of measuring to 0,5 °C.
A.1.2 Balance, weighing to 10 g.
A.1.3 Time measuring device (stopwatch), capable of measuring ± 0,1 s.
A.1.4 Container, for the determination of the volumetric flow rate for at least 20 l of water.
A.1.5 Plastic block, made of polystyrene rigid plastic foam.
The kind of the polystyrene rigid plastic foam shall be agreed by the interested parties.
A.1.6 Length measuring device, capable of measuring ± 0,1 mm.
A.2.4 Calibration of the water jet
The conditions for the calibration of the jetting are in accordance with method B. For the calibration of
the jetting, a stainless steel precision flat film extrusion die with a volumetric flow rate of the nozzle of
6 l/min at 2 MPa (20 bar) and a jet angle 25° is used. This nozzle is required to produce an even liquid
distribution during the entire jetting.
When using an automatic pressure-water apparatus, fasten the polystyrene rigid plastic foam in the
apparatus so that the jet cannot move the block. When using a manual apparatus, fasten the block in a
similar fixture.
After jetting, the length and the width of the impact are measured. See Figure A.1.
The mean length of the impact shall be (73 ± 5) mm and the mean width (8 ± 1) mm on average.


Figure A.1 — Measures of the washed-out areas in the polystyrene rigid plastic foam

 

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

X
該信息已收藏!
標簽:
保存成功

(空格分隔,最多3個,單個標簽最多10個字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時間回復您~
撥打電話
在線留言
主站蜘蛛池模板: 最近中文字幕久久久| 精品熟女少妇AV久久免费A片| 国产欧美日韩综合精品二区| 黄色网页免费看| 伦理片在线观看午夜伦理电影三级网| 欧美一级片内射美女少妇| 毛片内射-百度| 色婷婷影院在线视频免费播放| 荫蒂添的好舒服嗯快嗯呢来了视频| 久久99亚洲精品久久频| 国产精品美女久久久浪潮av| 欧美在线精品播放| 欧美丰满人妻视频中文字幕| 免费欧美日韩网站| 亚洲性夜色噜噜噜网站2258KK| 国产精品亚洲欧美一区麻豆| 精品久久久久久无码人妻国产馆| 性欧美video另类hd尤物| 国产日韩中文字幕| 一边摸一边叫床一边爽| 亚洲综合无码一区二区| 黑人巨茎精品欧美一区二区| 久久66热这里只有精品| 国产成人精品久久999| 久久久精品日本一区二区三区| 午夜精品射精入后重之免费观看| 中文日产无乱码AV在线观| 欧美国产精品粉嫩在线播放| 在线看片福利无码网址| 日韩欧美综合网站| 久久久久久国产a免费观看黄色大片| 久久中文字幕日韩精品| 黄色片app| 欧美一区二区三区在线bbb| 国产麻豆久久精品| 99国产精品久久久久久久日本竹| 被病娇做到哭H| 一边做一边说国语对白| 男人狂躁进女人免费视频公交| 成人无码在线视频网站| 艳情欲色爱乱小说|