AP033 provides a range of sensitivities from x10 gain to ÷10 attenuation for diverse signals

詳細(xì)介紹

力科有源差分探頭簡單介紹:

Fully Integrated: With the ProBus? interface, the AP033 becomes an integral part of the oscilloscope. The probe sensitivity and offset can be controlled from the oscilloscope front panel, the probe front panel, or by using remote control commands (GPIB or RS-232). Sensitivity, offset, input capacitance, and common mode voltage range are displayed on the oscilloscope screen. When used with a LeCroy digital oscilloscope, no external power supply is required.

Wide Dynamic Range: The AP033 provides a range of sensitivities from x10 gain to ÷10 attenuation (even ÷100 with plug-on attenuator) for diverse signals. The sensitivity can be adjusted continuously from 200 μV/div to 1 V/div, when used with a LeCroy oscilloscope.

At high sensitivities, the x10 GAIN and the ÷1 ATTENUATION are selected. This produces 4 nV/√Hz input noise, ±5 V of common mode voltage range (CMVR), and ±400 mV of DC differential offset. At lower sensitivities, the x1 GAIN and ÷10 ATTENUATION are selected, resulting in ±50 V CMVR and ±4 V of differential offset.

The input capacitance is just 2 pF/side (1 pF differential) whenever the ÷10 ATTENUATION is selected. Deflection factors of 2 mV/div to 1 V/div can be obtained with only 2 pF/side input capacitance and ±50 V CMVR.

DC CMRR is greater than 10,000:1 (80 dB) in both ATTENUATION settings.

OFFSET up/down buttons allow OFFSET control from the probe amplifier body. Momentarily holding both buttons will zero the OFFSET.

A supplied AC coupling capacitor head (0.1 μF) allows operation with large common mode or differential DC inputs.

The input attenuator automatically changes from ÷1 to ÷10 when too much common mode signal is sensed. This and a fast input protection circuit also serve to protect the input from potentially damaging signals. When the probe is removed from the oscilloscope or the power is turned off, the ÷10 ATTENUATION is automatically invoked, leaving the inputs protected when not in use.

Gain and Attenuation Selections
The AP033 consists of a probe head with ÷1 or ÷10 attenuation and an amplifier body which attaches to the scope front panel. The amplifier gain can be either x1 and x10. Both the probe head attenuator and amplifier gain are controlled through the ProBus interface. Normally the GAIN and ATTENUATION selections are accomplished by the oscilloscope as shown in the table below.

There are two ways of obtaining x1 gain from the AP033: x1 GAIN with ÷1 ATTENUATION, or x10 GAIN with ÷10 ATTENUATION. The oscilloscope selects the latter of these two options (as shown below) to provide minimum input capacitance and maximum common-mode dynamic range while still leaving low noise operation available at the highest sensitivity.

By using the probe amplifier body control to override the automatic selection, the x1 GAIN with ÷1 ATTENUATION option is readily available for 10 mV, 20 mV and 50 mV/div. CMVR is ±5 V, input capacitance is 5 pF, and noise is 9 nV/√Hz. Similarly, x10 GAIN and ÷10 ATTENUATION can be selected at 2 mV/div and 5 mV/div for 2 pF input C and ±50 V CMVR. The oscilloscope displays the correct deflection factor in all cases.

Using the supplied accessory plug-on attenuator head, gain selections from 100 mV/div to 10 V/div are available.

Input Characteristics
The input capacitance is modeled by 2 pF to ground from each input plus 0.20 pF from input to input when the ÷10 ATTENUATION is selected. This is equivalent to 1.20 pF differential input capacitance. With ÷1 ATTENUATION, the differential input capacitance is 2.7 pF.

Input resistance is 1 Mohm at all GAIN and ATTENUATOR settings, including the accessory plug-on attenuator head.

An AC coupling plug-on accessory features a 0.1 μF coupling capacitor for each input. The low-frequency CMRR is reduced.

Autobalance

Holding both offset buttons down for two seconds with the input connections removed invokes Autobalance. This provides the highest accuracy on all ranges by removing residual DC offset from the probe.

Low Noise

At full gain, the noise is less than 4 nV/√Hz, the lowest of any available differential probe.

Common Mode Sensing and Input Protection

It is not uncommon for a differential amplifier to be connected to a signal whose common- mode voltage exceeds the amplifier''s common-mode range. Faulty readings, including total loss of signal, can result. The AP033 senses when signals exceed ±5.5 V and switches its input attenuator into the signal path. The oscilloscope shows the new deflection factor, and the probe continues to work.

The same mechanism protects the probe from damage due to large input signals. The probe amplifier is protected from large, fast-rising signals until the input attenuator can provide permanent protection. This takes about 1 ms. With the input attenuator in place, the input can withstand 200 V DC indefiniy.

收藏該商鋪

登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時間回復(fù)您~
二維碼 意見反饋
在線留言
主站蜘蛛池模板: 男人放进女人阳道动态图| 国产亚洲情侣久久精品| 欧美日韩国产亚洲沙发| 手机在线亚洲欧美日韩| 欧美精品一级片大全| 精品久久久久久毛片| 欧美日韩免费高清| 免费看欧美成人A片无码| 日韩 国产 在线观看| 久久久久久久久| 一本色道久久综合无码人妻| 出差被公添到高潮A片视频| 含着不拔出来 H 1V1| 午夜亚洲国产理论片二级港台二级| 亚洲桃色天堂网| 欧美激情四射在线| 色妞色视频一区二区三区四区| 无码又黄又爽又舒服的A片| 国产在线精品视频二区| 五月天激情小说| 欧美日韩激情亚洲国产| 久久精品国产在热久久2019| 欧美精品久久久久久精华液| 色偷偷国色天香在线观看免费视频| 国产精品精品久久久久| 午夜DV内射一区二区| 两个女人互添下身爽舒服小说| 亚洲在线日韩在线| 久久精品国产在热久久| 久久99AV无色码人妻蜜| 亚洲精品无码国产爽快A片百度| 欧美激情xxbb| 亚洲一区精品在线| 男男扒开小受双腿进入gv视频| 亚洲男人天堂偷拍| 日本高清不卡码中文字幕| 国产日韩欧美高清免费视频| 一区二区三区四区欧美精品| 无码欧美激情性做爰免费| 三级在线日韩中文| 欧美日韩免费高清|