江蘇安科瑞電器制造有限公司

Application of ASJ Residual Current Relay

時間:2021-3-22閱讀:598
分享:

安科瑞 鮑靜君

  Abstract: the necessity of applying residual current, the main functions, working principle, classification situation of ASJ residual current relay are introduced, and the principles and precautions in selecting residual current protection circuit breaker are indicated. This is a brief introduction about the addition of our company application of ASJ residual current relay in a generator set project in Maldives.

  Keywords: ASJ residual current relay; generator set; application.

  1. Project overview

  This project is located in Maldives. The purpose of the residual current relay installed is to detect the residual current and compare the residual current value with the base value. When the residual current value exceeds the base value, it will send out a mechanical on-off signal (to make the mechanical switch tripped or the acousto-optic alarm device send out an alarm).Residual current relay usually with low voltage circuit breaker or low voltage contactor, etc combined residual current protection device, mainly applied to ac 50 hz, rated voltage 400 v and below the TT and TN system distribution circuit, used to ground fault protection electric circuit, prevent equipment damage caused by ground fault current and electrical fire accident, also can be used to provide indirect contact to person get an electric shock risk protection, and therefore is widely used in low voltage power supply and distribution system.

  2. Main uses of residual current relay

  2.1  Protection of Indirect Contact Electric Shock

  The measure of indirect contact electric shock protection is to automatically cut off the power supply. GB 13955" the protection of indirect contact electric shock accident "stipulates :" the main measure of indirect contact electric shock accident protection is to adopt the protection mode of automatically cutting off the power supply to prevent the damage accident caused by the insulation damage of electrical equipment. When the circuit insulation damage caused by grounding fault. When the fault current value is less than the operating current value of the over-current protection device, the residual current protection device shall be installed ." According to the research, the safe value of contact voltage is 50V. For personal safety, when insulation failure occurs in any part of the electrical device, once the contact voltage exceeds 50V, it is necessary to automatically cut off the fault part of the power supply within the specified time. The over-current protection device is limited by the electrical circuit and equipment and its own action value, and can not automatically cut off the power supply. The residual current protection device is not affected by the load current and can be used in conjunction with the over-current protection device for indirect contact electric shock protection.

  2.2  Ground fault protection

  Grounding is the contact between a live conductor and the earth, a grounded metal shell or a component connected to the ground. Its failure may lead to personal electric shock casualties and equipment damage, and may cause electrical fire in serious cases. Ground fault protection used to be protected by over-current protection device. When the grounding fault current is greater than the fixed value of the over-current protection device, the fault circuit is cut off by the over-current protection device.

  In TT system, the line with larger rated current and longer distribution line, grounding fault of live conductor, unsafe metallic grounding fault and arc grounding fault in TN system may occur that the grounding fault current is less than the setting current of over-current protection action, and the over-current protection device does not act. Residual current protection device, or circuit breaker with ground fault protection, can reliably carry out ground fault protection.

  2.3  Electrical fire protection

  Electrical fire is usually caused by electrical short circuit, which includes metal short circuit and arc short circuit. The former is a short circuit between live conductors (such as between phases, between phases and N lines). The fault current is calculated in kilo ampere. High temperature is easy to cause insulation oxidation and spontaneous combustion.

  Although the fire hazard is great, it can be protected by circuit breakers and fuses with short circuit protection, and the power supply is cut off by instantaneous action of circuit breaker to avoid fire. The latter is a live conductor short circuit to the ground, mostly arc as the path, although the fault current is small, but on the one hand, the arc lasts for a long time, the local temperature is high, it is easy to ignite the surrounding combustible material and cause fire. Therefore, the fire hazard caused by arc short circuit is much greater than that of metal short circuit. The circuit breaker with residual current action protection function can cut off the support circuit without the operation of the over-current protection device to prevent the electrical fire caused by the arc short circuit.

  3. ASJ Series of Residual Current Relay

  3.1  Model & Function

3.2  Technical Parameters

  3.3 Typical Application Schematic

  4. Pictures of the installation of the residual current relay on the generator set project site

  5. Summary

  Acrel ASJ series of residual current relays have been applied in many occasions, such as industry, civil, subway, intelligent building and so on, which has played a good protective effect and is worth promotional use.

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

X
該信息已收藏!
標簽:
保存成功

(空格分隔,最多3個,單個標簽最多10個字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時間回復您~

以上信息由企業自行提供,信息內容的真實性、準確性和合法性由相關企業負責,化工儀器網對此不承擔任何保證責任。

溫馨提示:為規避購買風險,建議您在購買產品前務必確認供應商資質及產品質量。

撥打電話
在線留言
主站蜘蛛池模板: 久久中文字幕无码A片不卡| H女主从小被C到大荤话小说| 求个色网站| 欧美av大片在线观看| 日韩欧美国产看片| 产品精品自在在线午夜免费| 韩国精品一区二区三区四区| 亚洲A片7777KKKKK| 欧美黄色一级视频| av毛片久久久久| 国产欧美国日产在线播放| 女人张腿让男人桶免费| 国产亚洲精品中文带字幕| 亚洲精品一区二区三区无码A片| 老师你下面太紧进不去小黄文| 精品一区二区三区免费毛片| 国产亚洲精品第一综合麻豆| 毛片av永久在线观看| 麻豆文化传媒网站官网免费| 久久噜噜噜精品国产亚洲综合| 欧美日韩一二级片| 在线欧美亚洲综合网站| 欧美精品久久久久久宅男| 亚洲巨乳日本无码一二三区| 欧美一区二区三区四区久久| 国产永久一区二区三区| 男女无遮挡猛进猛出免费观看视频| 亚洲区色情区激情区小说风尘劫| 蜜桃av少妇久久久久久高| 久久精品7| 日本电影一区二区三区| 亚洲成人自拍网| 色伦专区97中文字幕| 伊人久久大香线蕉综合99| 帅哥摸舔美女全身视频| 媚薬女教师中文字幕在线| 校园高H校草深一点H| 神马影院我不卡| 国产日韩每日更新| 国内精品乱码卡一卡2卡三卡| 国产美女精品福利在线|