Application of Acrel Earth Leakage Relay in Intell

時間:2021-1-8閱讀:429
分享:

Acrel Rebecca(鮑靜君)

  Abstract: the necessity of applying residual current relay in intelligent building is analyzed, the main functions, working principle, classification situation of ASJ residual current relay are introduced, and the principles and precautions in selecting residual current protection circuit breaker are indicated.

  Keywords: ASJ residual current relay; intelligent building; application.

  1. Background

  The residual current relay is to detect the residual current and compare the residual current value with the reference value. When the residual current value exceeds the reference value, An electrical appliance that sends out a mechanical opening and closing signal. The residual current relay is usually composed of a combined residual current protection device with low voltage circuit breaker or low voltage contactor. It is mainly suitable for TT and TN system distribution lines with rated voltage of 50 Hz, and below. It can also provide indirect contact protection for personal electric shock, so it can be widely used in intelligent building power supply and distribution system.

  2. Main uses of residual current relay

  2.1  Protection of Indirect Contact Electric Shock

  The measure of indirect contact electric shock protection is to automatically cut off the power supply. GB 13955" the protection of indirect contact electric shock accident "stipulates :" the main measure of indirect contact electric shock accident protection is to adopt the protection mode of automatically cutting off the power supply to prevent the damage accident caused by the insulation damage of electrical equipment. When the circuit insulation damage caused by grounding fault. When the fault current value is less than the operating current value of the over-current protection device, the residual current protection device shall be installed ." According to the research, the safe value of contact voltage is 50V. For personal safety, when insulation failure occurs in any part of the electrical device, once the contact voltage exceeds 50V, it is necessary to automatically cut off the fault part of the power supply within the specified time. The over-current protection device is limited by the electrical circuit and equipment and its own action value, and can not automatically cut off the power supply. The residual current protection device is not affected by the load current and can be used in conjunction with the over-current protection device for indirect contact electric shock protection.

  2.2  Ground fault protection

  Grounding is the contact between a live conductor and the earth, a grounded metal shell or a component connected to the ground. Its failure may lead to personal electric shock casualties and equipment damage, and may cause electrical fire in serious cases. Ground fault protection used to be protected by over-current protection device. When the grounding fault current is greater than the fixed value of the over-current protection device, the fault circuit is cut off by the over-current protection device.

  In TT system, the line with larger rated current and longer distribution line, grounding fault of live conductor, unsafe metallic grounding fault and arc grounding fault in TN system may occur that the grounding fault current is less than the setting current of over-current protection action, and the over-current protection device does not act. Residual current protection device, or circuit breaker with ground fault protection, can reliably carry out ground fault protection.

  2.3  Electrical fire protection

  Electrical fire is usually caused by electrical short circuit, which includes metal short circuit and arc short circuit. The former is a short circuit between live conductors (such as between phases, between phases and N lines). The fault current is calculated in kilo ampere. High temperature is easy to cause insulation oxidation and spontaneous combustion.

  Although the fire hazard is great, it can be protected by circuit breakers and fuses with short circuit protection, and the power supply is cut off by instantaneous action of circuit breaker to avoid fire. The latter is a live conductor short circuit to the ground, mostly arc as the path, although the fault current is small, but on the one hand, the arc lasts for a long time, the local temperature is high, it is easy to ignite the surrounding combustible material and cause fire. Therefore, the fire hazard caused by arc short circuit is much greater than that of metal short circuit. The circuit breaker with residual current action protection function can cut off the support circuit without the operation of the over-current protection device to prevent the electrical fire caused by the arc short circuit.

  3. ASJ Series of Residual Current Relay

  3.1 Model & Function

3.2 Technical Parameters

  3.3 Typical Application Schematic

  4.Examples of application of residual current relay in intelligent building

  4.1Intelligent residential buildings and hotel rooms

  The electric iron, hair dryer and electric kettle in residential and hotel have high frequency of use, which are prone to wire breakage and water splashing to socket, which seriously endanger personal safety and need to monitor leakage current and protect it. The residual current relay is installed in the intelligent residential building and hotel room, which can cut off the power supply and protect the personal safety in the case of leakage or electric shock.

  4.2 Swimming Pool in Intelligent Building

  Modern sports fields and hotels are mostly intelligent buildings with swimming pool. In order to ensure the swimming pool is clean, the general swimming pool is equipped with circulating water pump system. Swimming pool is a crowded place. In order to ensure the safety of personnel, the circulating water pump system of swimming pool should be equipped with residual current relay. Ensure timely tripping, cutting off power supply and protecting personal safety when leakage fault occurs in circulating water pump system.

  4.3 Intelligent construction site

  Intelligent construction sites are commonly used to bulk cement and concrete mixers, tower cranes and other construction machinery, hand drills, cutting machines and other mobile power tools, need to supply them temporary power. The general construction site environment is wet, the personnel is numerous, the structure is complex, the electric equipment is mostly mobile, and the distribution line is long and complex, easy to be damaged by the external force, it is easy to cause the leakage and endanger the safety of personnel. Therefore, the residual current relay with rated residual current about 30mA should be set up in the construction site.

  5.Summary

  Acrel ASJ series of residual current relays have been applied in many occasions, such as industry, civil, subway, intelligent building and so on, which has played a good protective effect and is worth promotional use.

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

X
該信息已收藏!
標簽:
保存成功

(空格分隔,最多3個,單個標簽最多10個字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時間回復您~

以上信息由企業自行提供,信息內容的真實性、準確性和合法性由相關企業負責,化工儀器網對此不承擔任何保證責任。

溫馨提示:為規避購買風險,建議您在購買產品前務必確認供應商資質及產品質量。

撥打電話
在線留言
主站蜘蛛池模板: 啊就是那里快嗯别停| 欧美亚洲国产日韩综合| 欧美日韩另类亚洲| 久久无码AV亚洲精品色午夜| 五月天久久久久久久久| 欧美日韩中文字幕久久| 综合激情五月丁香久久| 国模私拍一区二区三区| 扒开老师双腿猛进入白浆小说| 婷婷欧美一区二区三区四区| 国产AV午夜精品一区二区入口| 长篇YIN荡乱岳合集| 亚洲天天干| 色鲁阁色婷婷色丁香| 吉吉影音成 人影院6655| 免费无码片AV在线观看| 日日天干夜夜狠狠爱| 欧美一级夜夜爽| 亚洲AV久久无码精品九九小说| 中文字幕 偷拍| 欧美日韩精品久久| 成人免费区一区二区三区| 色翁荡息又大又硬又粗肖艳| 久久成人国产精品免费| 国产精品 日韩欧美| 美女祼体添鸡把图片| 久久久久久久久久久艹| 久久精品黄AA片一区二区三区| 苍井空亚洲精品AA片在线播放| 日韩黄色av一级片| 全黄H全肉短篇禁乱NP慕浅浅| 欧美日韩一级内射可以看-| 日本高清在线一区二区三区| 色噜噜噜AV亚洲男人的天堂| 色欲久久精品AV无码| 亚洲一级无码免费视频| 欧美日韩国产另类综合| 久久久久久久久| 国产内射爽爽大片| 欧美美女一区二区三区| 国产午夜福利久久精品|