 Human bone alkaline phosphatase (BALP) ELISA Kit
Catalog No. CSB-E09033h
(96 T)
This immunoassay kit allows for the in vitro quantitative determination of human BALP concentrations in serum, plasma a-n-d other biological fluids.
Expiration date six months from the date of manufacture
FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
廈門慧嘉生物長期經(jīng)營ELISA試劑盒及Santa/Abcam抗體、Prospec細(xì)胞因子、Sigma/Amresco/Qiagen、Axygen耗材等生物試劑產(chǎn)品。誠信經(jīng)營,為客戶提供“zui高質(zhì)量的產(chǎn)品”和“zui的服務(wù)”:   :  1048735792 或登陸http://www.biohj.com(向客服人員索取原版說明書)。歡迎廣告老師來詢!
 
PRINCIPLE OF THE ASSAY
The microtiter plate provided in this kit has been pre-coated with an antibody specific to BALP. Sta-n-dards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody preparation specific for BALP a-n-d Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well a-n-d incubated. Then a TMB (3,3',5,5' tetramethyl-benzidine) substrate solution is added to each well. Only those wells that contain BALP, biotin-conjugated antibody a-n-d enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution a-n-d the color change is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of BALP in the samples is then determined by comparing the O.D. of the samples to the sta-n-dard curve.
DETECTION RANGE
3.12 ng/ml-200 ng/ml. The sta-n-dard curve concentrations used for the ELISA’s were 200 ng/ml, 100 ng/ml, 50 ng/ml, 25 ng/ml,
12.5 ng/ml, 6.25 ng/ml, 3.12 ng/ml.
SPECIFICITY
This assay recognizes recombinant a-n-d natural human BALP. No significant cross-reactivity or interference was observed.
SENSITIVITY
The minimum detectable dose of human BALP is typically less than 0 .78 ng/ml. The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero.
MATERIALS PROVIDED STORAGE

Reagent
Quantity
Assay plate
1
Standard
2
Sample Diluent
1 x 20 ml
Biotin-antibody Diluent
1 x 10 ml
HRP-avidin Diluent
1 x 10 ml
Biotin-antibody
1 x 120μl
HRP-avidin
1 x 120μl
 
1 x 20 ml
Wash Buffer
 
 
(25×concentrate)
TMB Substrate
1 x 10 ml
Stop Solution
1 x 10 ml

 
1.    Unopened test kits should be stored at 2-8?C upon receipt a-n-d the microtiter plate should be kept in a sealed bag. The test kit may be used throughout the expiration date of the kit, provided it is stored as prescribed above. Refer to the package label for the expiration date.
2.    Opened test plate should be stored at 2-8?C in the aluminum foil bag with desiccants to minimize exposure to damp air. The kits will remain stable until the expiring date shown, provided it is stored as prescribed above.
3.    A microtiter plate reader with a ba-n-dwidth of 10 nm or less a-n-d an optical density range of 0-3 OD or greater at 450nm wavelength is acceptable for use in absorbance measurement.
 
REAGENT PREPARATION
Bring all reagents to room temperature before use.
1         Wash Buffer If crystals have formed in the concentrate, warm up to room temperature a-n-d mix gently until the crystals have compley dissolved. Dilute 20 ml of Wash Buffer Concentrate into deionized or distilled water to prepare 500 ml of Wash Buffer.
2         Sta-n-dard Centrifuge the sta-n-dard vial at 6000-10000rpm for 30s. Reconstitute the Sta-n-dard with 1.0 ml of Sample Diluent. This reconstitution produces a stock solution of 200 ng/ml. Allow the sta-n-dard to sit for a minimum of 15 minutes with gentle agitation prior to making serial dilutions. The undiluted sta-n-dard serves as the high sta-n-dard (200 ng/ml). The Sample Diluent serves as the zero sta-n-dard (0 ng/ml). Prepare fresh for each assay. Use within 4 hours a-n-d discard after use.
3         Biotin-antibody Centrifuge the vial before opening. Dilute to the working concentration using Biotin-antibody Diluent(1:100), respectively.
4         HRP-avidin Centrifuge the vial before opening. Dilute to the working concentration using HRP-avidin Diluent(1:100), respectively.
 
Precaution: The Stop Solution provided with this kit is an acid solution. Wear eye, ha-n-d, face, a-n-d clothing protection when using this material.
OTHER SUPPLIES REQUIRED
1          Microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm.
2          Pipettes a-n-d pipette tips.
3          Deionized or distilled water.
4          Squirt bottle, manifold dispenser, or automated microplate washer.
5          An incubator which can provide stable incubation conditions up to 37°C±0.5°C.
 
SAMPLE COLLECTION A-N-D STORAGE
Serum Use a serum separator tube (SST) a-n-d allow samples to clot for 30 minutes before centrifugation for 15 minutes at 1000 g. Remove serum a-n-d assay immediay or aliquot a-n-d store samples at -20°C. Centrifuge the sample again after thawing before the assay. Avoid repeated freeze-thaw cycles.
Plasma Collect plasma using citrate, EDTA, or heparin as an anticoagulant. Centrifuge for 15 minutes at 1000 g within 30 minutes of collection. Assay immediay or aliquot a-n-d store samples at -20°C. Centrifuge the sample again after thawing before the assay. Avoid repeated freeze-thaw cycles.
 
Note: Grossly hemolyzed samples are not suitable for use in this assay.
ASSAY PROCEDURE
Bring all reagents a-n-d samples to room temperature before use. It is recommended that all samples, sta-n-dards, a-n-d controls be assayed in duplicate. All the reagents should be added directly to the liquid level in the well. The pipette should avoid contacting the inner wall of the well.
1         Add 100μl of Sta-n-dard, Blank, or Sample per well. Cover with the adhesive strip. Incubate for 2 hours at 37°C.
2         Remove the liquid of each well, don’t wash.
3         Add 100μl of Biotin-antibody working solution to each well. Incubate for 1 hour at 37°C. Biotin-antibody working solution may appear cloudy. Warm up to room temperature a-n-d mix gently until solution appears uniform.
4         Aspirate each well a-n-d wash, repeating the process three times for a total of three washes. Wash: Fill each well with
 
Wash Buffer (200μl) a-n-d let it sta-n-d for 2 minutes, then
remove the liquid by flicking the plate over a sink. The remaining drops are removed by patting the plate on a paper towel. Complete removal of liquid at each step is essential to good performance.
 
1         Add 100μl of HRP-avidin working solution to each well. Cover the microtiter plate with a new adhesive strip. Incubate for 1 hour at 37°C.
2         Repeat the aspiration a-n-d wash five times as step 4.
3         Add 90μl of TMB Substrate to each well. Incubate for 10-30 minutes at 37°C. Keeping the plate away from drafts a-n-d other temperature fluctuations in the dark.
4         Add 50μl of Stop Solution to each well when the first four wells containing the highest concentration of sta-n-dards develop obvious blue color. If color change does not appear uniform, gently tap the plate to ensure thorough mixing.
5         Determine the optical density of each well within 30 minutes, using a microplate reader set to 450 nm.
 
CALCULATION OF RESULTS
Using the professional soft "Curve Exert 1.3" to make a sta-n-dard curve is recommended, which can be downloaded from our web.
Average the duplicate readings for each sta-n-dard, control, a-n-d sample a-n-d subtract the average zero sta-n-dard optical density. Create a sta-n-dard curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a sta-n-dard curve by plotting the mean absorbance for each sta-n-dard on the y-axis against the concentration on the x-axis a-n-d draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the BALP concentrations versus the log of the O.D. a-n-d the best fit line can be determined by regression analysis. This procedure will produce an adequate but less precise fit of the data. If samples have been diluted, the concentration read from the sta-n-dard curve must be multiplied by the dilution factor.
LIMITATIONS OF THE PROCEDURE
1          The kit should not be used beyond the expiration date on the kit label.
2          Do not mix or substitute reagents with those from other lots or sources.
3          It is important that the Sta-n-dard Diluent selected for the sta-n-dard curve be consistent with the samples being assayed.
4          If samples generate values higher than the highest sta-n-dard, dilute the samples with the appropriate Sta-n-dard Diluent a-n-d repeat the assay.
5          Any variation in Sta-n-dard Diluent, operator, pipetting technique, washing technique, incubation time or temperature, a-n-d kit age can cause variation in binding.
6          This assay is designed to eliminate interference by soluble receptors, binding proteins, a-n-d other factors present in biological samples. Until all factors have been tested in the Quantikine Immunoassay, the possibility of interference cannot be excluded.
 
TECHNICAL HINTS
1          Centrifuge vials before opening to collect contents.
2          When mixing or reconstituting protein solutions, always avoid foaming.
3          To avoid cross-contamination, change pipette tips between additions of each sta-n-dard level, between sample additions, a-n-d between reagent additions. Also, use separate reservoirs for each reagent.
4          When using an automated plate washer, adding a 30 second soak period following the addition of wash buffer, a-n-d/or rotating the plate 180 degrees between wash steps may improve assay precision.
5          To ensure accurate results, proper adhesion of plate sealers during incubation steps is necessary.
6          Substrate Solution should remain colorless or light blue until added to the plate. Keep Substrate Solution protected from light. Substrate Solution should change from colorless or light blue to gradations of blue.
7          Stop Solution should be added to the plate in the same order as the Substrate Solution. The color developed in the wells will turn from blue to yellow upon addition of the Stop Solution. Wells that are green in color indicate that the Stop Solution has not mixed thoroughly with the Substrate Solution.

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗(yàn)證碼

收藏該商鋪

X
該信息已收藏!
標(biāo)簽:
保存成功

(空格分隔,最多3個,單個標(biāo)簽最多10個字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時間回復(fù)您~
撥打電話
在線留言
主站蜘蛛池模板: 欧美性生交XXXXX无码影院| 日韩欧美精品一区在线| 成人国产精品一级毛片视频| 国产精品成人亚洲| 亚洲欧美日韩精品色xxx| 中文字幕一人妻厨房被公| 被群CAO的合不拢腿H两根一起| 亚洲一区二区黄色| 100%TUBEXXXXHD| 久久亚洲精品无码Va白人极品| 日本高清不卡码中文字幕| 一女六男NP慎入H| 日韩免费一区二区三区在线| 亚洲欧美日韩人成| A级韩国乱理伦片在线观看| 91国产视频在线观看| 国产男人午夜视频在线观看| 亚洲欧美精品中文字幕在线| 免费观看又色又爽又黄的小说校园| 久久久久久久伊人电影| 91在线视频观看国产| 欧美一区二区三区精品a∨| 国产91精品网站在线观看| 色偷偷资源亚洲在线| 精品国产乱码久久久久久虫虫| 日韩在线亚洲一区| 欧洲性xxxx免费视频下载软件| 国产亚洲欧美日韩在线观看| 44西西人体做爰大胆视频| 亚洲五月综合缴情综合久久本| 神马电影院我不卡影院| 久久精品国产亚洲欧美| 欧美日韩中文字幕视频| 高H纯肉NP 弄潮NP男男| 久久这里只精品国产免费9| 欧美午夜乱理片无码视频| 51久久国产露脸精品国产| 97精品人人A片免费看| 91九色在线精品| 大香蕉国产成人在线| 91精品国产免费久久久久久|