CSB-E07348r大鼠血管內皮細胞生長因子受體2(VEGFR-2)ELISA試劑盒說明書

時間:2012/2/14閱讀:481
分享:

 

Rat Vascuoar Endothelial Cell Growth Factor Receptor 2(VEGFR-2/Flk-1) ELISA kit    
 
Catalog No. CSB-E07348r (96 T)       
 
l This immunoassay kit allows for the in vitro quantitative determination of rat VEGFR-2/Flk-1 concentrations in serum, plasma.
l Expiration date   six months from the date of manufacture
l FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
 
  廈門慧嘉生物長期經營ELISA試劑盒及Santa/Abcam抗體、Prospec細胞因子、Sigma/Amresco/Qiagen、Axygen耗材等生物試劑產品。誠信經營,價格實惠,服務周到,質量有保證。歡迎廣告老師來詢!:   :  1048735792 或登陸http://www.biohj.com/download.aspx(向客服人員索取原版說明書)
 
INTRODUCTION
Vascular endothelial cell growth factor (VEGF), also known as vascular permeability factor, is an endothelial cell mitogen, which stimulates angiogenesis by binding to specific receptors (VEGFRs) on the surface of vascular endothelial cells. The VEGF liga-n-d/receptor signaling system plays a key role in vascular development a-n-d regulation of vascular permeability. All the three receptors for VEGF, VEGFR1~3, belong to CSF-1/PDGF receptor subfamily of receptor tyrosine kinase superfamily (RTKs), a-n-d contains seven Ig-like C2-type domains in the ECD, as well as a intracellular protein kinase domain. VEGFR2, also called as KDR or Flk-1, is identified as the receptor for VEGF a-n-d VEGFC a-n-d an early marker for endothelial cell progenitors, whose expression is restricted to endothelial cells in vivo. The adaptor protein SHB has been shown to interact with VEGFR2 in receptor tyrosine kinase signaling. In addition, VEGFR2 is able to interact with HIV-1 extracellular Tat protein upon VEGF activation, a-n-d seems to enhance angiogenesis in Kaposi's sarcoma lesions.
PRINCIPLE OF THE ASSAY The microtiter plate provided in this kit has been pre-coated with an antibody specific to VEGFR-2/Flk-1. Sta-n-dards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated polyclonal antibody preparation specific for VEGFR-2/Flk-1 a-n-d Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well a-n-d incubated. Then a TMB (3,3',5,5' tetramethyl-benzidine) substrate solution is added to each well. Only those wells that contain VEGFR-2/Flk-1, biotin-conjugated antibody a-n-d enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution a-n-d the color change is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of VEGFR-2/Flk-1 in the samples is then determined by comparing the O.D. of the samples to the sta-n-dard curve. DETECTION RANGE 0.31 ng/ml-20 ng/ml. The sta-n-dard curve concentrations used for the ELISA’s were 20 ng/ml, 10 ng/ml, 5 ng/ml, 2.5 ng/ml, 1.25 ng/ml, 0.63 ng/ml, 0.31 ng/ml.
SPECIFICITY This assay recognizes recombinant a-n-d natural rat VEGFR-2/Flk-1. No significant cross-reactivity or interference was observed. SENSITIVITY The minimum detectable dose of rat VEGFR-2/Flk-1 is typically less than 0.08 ng/ml. The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero. MATERIALS PROVIDED

Reagent  
Quantity
Assay plate
1
Standard
2
Sample Diluent  
1 x 20 ml
Biotin-antibody Diluent  
1 x 10 ml
HRP-avidin Diluent   
1 x 10 ml
Biotin-antibody  
1 x 120μl
HRP-avidin
1 x 120μl
Wash Buffer   
1 x 20 ml (25×concentrate)
TMB Substrate  
1 x 10 ml
Stop Solution  
1 x 10 ml

STORAGE
1. Unopened test kits should be stored at 2-8?C upon receipt a-n-d the microtiter plate should be kept in a sealed bag. The test kit may be used throughout the expiration date of the kit. Refer to the package label for the expiration date.
2. Opened test kits will remain stable until the expiring date shown, provided it is stored as prescribed above.  
3. A microtiter plate reader with a ba-n-dwidth of 10 nm or less a-n-d an optical density range of 0-3 OD or greater at 450nm wavelength is acceptable for use in absorbance measurement.
 
REAGENT PREPARATION Bring all reagents to room temperature before use. 
1. Wash Buffer  If crystals have formed in the concentrate, warm up to room temperature a-n-d mix gently until the crystals have compley dissolved. Dilute 20 ml of Wash Buffer Concentrate into deionized or distilled water to prepare 500 ml of Wash Buffer.
 
 
2. Sta-n-dard  Centrifuge the sta-n-dard vial at 6000-10000rpm for 30s. Reconstitute the Sta-n-dard with 1.0 ml of Sample Diluent. This reconstitution produces a stock solution of 20 ng/ml. Allow the sta-n-dard to sit for a minimum of 15 minutes with gentle agitation prior to making serial dilutions. The undiluted sta-n-dard serves as the high sta-n-dard (20 ng/ml). The Sample Diluent serves as the zero sta-n-dard (0 ng/ml). Prepare fresh for each assay. Use within 4 hours a-n-d discard after use.
3. Biotin-antibody  Centrifuge the vial before opening. Dilute to the working concentration using Biotin-antibody Diluent(1:100),respectively. The suggested 100-fold dilution can be achieved by adding 10 uL sample to 990uL of Biotin-antibody Diluent for 1ml working solution. 
4. HRP-avidin  Centrifuge the vial before opening. Dilute to the working concentration using HRP-avidin Diluent(1:100), respectively. The suggested 100-fold dilution can be achieved by adding 10 uL sample to 990uL of HRP-avidin Diluent for 1ml working solution.
 
Precaution: The Stop Solution provided with this kit is an acid solution. Wear eye, ha-n-d, face, a-n-d clothing protection when using this material.
OTHER SUPPLIES REQUIRED
? Microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm.
? Pipettes a-n-d pipette tips.
? Deionized or distilled water.
? Squirt bottle, manifold dispenser, or automated microplate washer.
 
SAMPLE COLLECTION A-N-D STORAGE
l Serum Use a serum separator tube (SST) a-n-d allow samples to clot for 30 minutes before centrifugation for 15 minutes at 1000 g. Remove serum a-n-d assay immediay or aliquot a-n-d store samples at -20°C. Centrifuge the sample again after thawing before the assay. Avoid repeated freeze-thaw cycles.
l Plasma Collect plasma using citrate, EDTA, or heparin as an anticoagulant. Centrifuge for 15 minutes at 1000 g within 30 minutes of collection. Assay immediay or aliquot a-n-d store samples at -20°C. Centrifuge the sample again after thawing before the assay. Avoid repeated freeze-thaw cycles.
 
Note: Grossly hemolyzed samples are not suitable for use in this assay.
ASSAY PROCEDURE
Bring all reagents a-n-d samples to room temperature before use. It is recommended that all samples, sta-n-dards, a-n-d controls be assayed in duplicate. All the reagents should be added directly to the liquid level in the well. The pipette should avoid contacting the inner wall of the well.
1. Add 100μl of Sta-n-dard, Blank, or Sample per well. Cover with the adhesive strip. Incubate for 2 hours at 37° C. 
2. Remove the liquid of each well, don’t wash. 
3. Add 100μl of Biotin-antibody working solution to each well. Incubate for 1 hour at 37°C. Biotin-antibody working solution may appear cloudy. Warm up to room temperature a-n-d mix gently until solution appears uniform.
4. Aspirate each well a-n-d wash, repeating the process three times for a total of three washes. Wash: Fill each well with Wash Buffer (200μl) a-n-d let it sta-n-d for 2 minutes, then remove the liquid by flicking the plate over a sink. The remaining drops are removed by patting the plate on a paper towel. Complete removal of liquid at each step is essential to good performance.
5. Add 100μl of HRP-avidin working solution to each well. Cover the microtiter plate with a new adhesive strip. Incubate for 1 hour at 37°C.
 
 
6. Repeat the aspiration a-n-d wash five times as step 4.
7. Add 90μl of TMB Substrate to each well. Incubate for 10-30 minutes at 37°C. Keeping the plate away from drafts a-n-d other temperature fluctuations in the dark. 
8. Add 50μl of Stop Solution to each well when the first four wells containing the highest concentration of sta-n-dards develop obvious blue color. If color change does not appear uniform, gently tap the plate to ensure thorough mixing.
9. Determine the optical density of each well within 30 minutes, using a microplate reader set to 450 nm.
 
CALCULATION OF RESULTS Using the professional soft "Curve Exert 1.3" to make a sta-n-dard curve is recommended, which can be downloaded from our web.
Average the duplicate readings for each sta-n-dard, control, a-n-d sample a-n-d subtract the average zero sta-n-dard optical density. Create a sta-n-dard curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a sta-n-dard curve by plotting
the mean absorbance for each sta-n-dard on the y-axis against the concentration on the x-axis a-n-d draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the VEGFR-2/Flk-1 concentrations versus the log of the O.D. a-n-d the best fit line can be determined by regression analysis. This procedure will produce an adequate but less precise fit of the data. If samples have been diluted, the concentration read from the sta-n-dard curve must be multiplied by the dilution factor. LIMITATIONS OF THE PROCEDURE
? The kit should not be used beyond the expiration date on the kit label.
? Do not mix or substitute reagents with those from other lots or sources.
? It is important that the Calibrator Diluent selected for the sta-n-dard curve be consistent with the samples being assayed.
? If samples generate values higher than the highest sta-n-dard, dilute the samples with the appropriate Calibrator Diluent a-n-d repeat the assay.
 
 
? Any variation in Sta-n-dard Diluent, operator, pipetting technique, washing technique, incubation time or temperature, a-n-d kit age can cause variation in binding.
? This assay is designed to eliminate interference by soluble receptors, binding proteins, a-n-d other factors present in biological samples. Until all factors have been tested in the Immunoassay, the possibility of interference cannot be excluded.
 
TECHNICAL HINTS
? Centrifuge vials before opening to collect contents.
? When mixing or reconstituting protein solutions, always avoid foaming.
? To avoid cross-contamination, change pipette tips between additions of each sta-n-dard level, between sample additions, a-n-d between reagent additions. Also, use separate reservoirs for each reagent.
? When using an automated plate washer, adding a 30 second soak period following the addition of wash buffer, a-n-d/or rotating the plate 180 degrees between wash steps may improve assay precision.
 
 
? To ensure accurate results, proper adhesion of plate sealers during incubation steps is necessary.
? Substrate Solution should remain colorless until added to the plate. Keep Substrate Solution protected from light. Substrate Solution should change from colorless to gradations of blue.
? Stop Solution should be added to the plate in the same order as the Substrate Solution. The color developed in the wells will turn from blue to yellow upon addition of the Stop Solution. Wells that are green in color indicate that the Stop Solution has not mixed thoroughly with the Substrate Solution.
 
        

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

X
該信息已收藏!
標簽:
保存成功

(空格分隔,最多3個,單個標簽最多10個字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時間回復您~
撥打電話
在線留言
主站蜘蛛池模板: 亚瑟AV亚洲精品一区二区| 又硬又粗又大一区二区三区视频| 国产精品久久久久影视| 综合av成人在线播放| A片太大太长太深好爽A片视频| 性战美乳洋妞| 中文人妻AV久久人妻水密桃| 人妻久久久久久久久久久| 欧美日韩精品久久不| 艳情欲色爱乱小说| 久久久久久久久女人体| 国产一区二区精品久久| 国产亚洲精品久久久性色情软件| bl肉文推荐失禁| 欧美一区二区三区爽爽爽爽| 欧美大片在线观看aa| 51热门大瓜今日大瓜| 精品久久久久久久中文字幕| 国产大片内射1区2区| 麻豆文化传媒网站入口免费| 女人麻豆国产香蕉久久精品| 国产欧美亚洲精品a第一页| 蜜臀久久99精品久久久久久小说| 自拍区偷拍亚图片小说| 91久久国产精品91久久| 日本无码不遮挡又黄大尺度电影| 欧洲精品久久久av无码电影| 日韩欧美高清在线| 好久被狂躁A片视频无码免费视频| 日韩精品一区二区国产| 女人让男人桶爽30分钟小视频免费| 麻豆精品最新国产在线| 国产精品久久欧美久久一区| 三男一女的伦交| 亚洲精品色情APP在线下载观看| 黄色91制片厂| 性做久久久久久中文字幕| 日韩欧美国产成人在线| 日日噜噜大屁股熟妇AV张柏芝| 麻豆一区二区免费播放网站| 国产精品/综合区久久久久久|